BlueBOLT-Controllable Power Conditioner – 8 Outlets
Advanced 15 amp power controller with top of the line Linear Noise Filtration, Automatic Voltage Monitoring and catastrophic surge protection.
Features
Power Management with Control System Interactive Functionality.
- 15 Amp Capacity M4315-PRO
- 8 Individually Controllable Rear Panel Outlets
- Fully Programmable
- TCP/IP (BlueBOLT™) Installed
- Linear Filtration with 3 Isolated LiFT Filter Banks, 76db (5 kHz – 250 kHz), 46 db (250 kHz – 1 MHz)
- One Isolated Filter Bank for High Current Devices, 60db (5 kHz – 450 kHz), 46 db (450 kHz – 1 MHz)
- Front Panel Circuit Breaker
- Removable Front Rack Ears
- 12 Volt Input Triggering
- Detachable 10 ft. Power Cord
- AVM & Protect-or-Disconnect Circuitry
Specifications
Voltage Protection Rating (UL 1449 3rd Edition, 3,000A): 500V
Single Pulse Energy Dissipation: 2700 Joules
Peak Impulse Current: 135,000 Amps
LAN – Wires Protected: 8-Wires
LAN – Compatibility: 10/100/1000 BASE-T
LAN – Clamping Level: 60 ± 5V
Coax – Shielded: Yes
Coax – Insertion Loss: < 0.5 dB
Coax – HD 1080 i/p Ready: Yes
Coax – Frequency Range: 0 MHz – 2.2 GHz
Coax – Connections: Female “F”, Gold Plated
Coax – Clamping Level: 75V
Coax – Bidirectional: Yes
Other Specifications
- FamilyPro Series
- Line Voltage120 (Volts)
- Number of Outlets9
- Number of Isolated Banks4
- Outlet Descriptions
1 (always on, linearly filtered outlet, front panel)
6 (individually switchable, linearly filtered outlets)
2 (individually switchable, high current outlets)
- Rack MountableYes
- Rack Ears IncludedYes
- Front Panel Meter(s)Volts/Amps Combo Meter
- Front Media Light(s)No
- ControlFull outlet control using BlueBOLT or Telnet commands. Limited outlet control through front panel buttons or rear panel DC trigger.
- Voltage RegulationNo
- CompliancecCSAus
- USB ChargingN/A
- Low Voltage Trigger12V In
- AC Power Cord10 ft. detachable
- Dimensions19″ W (17″ without rack ears) x 12.25″ D x 1.75″ H
- Weight12 lbs
General
- AC Protection TechnologyProtect or Disconnect
Automatic Voltage Monitoring
L-N, L-G, N-G Protection Modes
Thermal Fusing - Under-Voltage Shutoff100 VAC ± 2 VAC
- Over-Voltage Shutoff134 VAC ± 2 VAC
- Maximum Current Rating15 (Amps)
- Initial Clamping Level200V Peak
AC Protection
- Filtration TechnologyLiFT
- Filtration Rating
Banks 1, 2, 3: 76db, 5KHz – 250 kHz
Bank 4 High Current Outlets: 46 db, 250 KHz – 1 Mhz
- Signal Line Protection1 LAN
1 Tel
2 Cable/Satellite
Filtration
- Length19.8 (Inches)
- Width4.6 (Inches)
- Height21.2 (Inches)
- Weight16.7 (Lbs)
- Unit of MeasureEach
- UPC050616008594
- Master Pack Qty2
Shipping Info
- Voltage Protection Rating (UL 1449 3rd Edition, 3,000A)500V
- Single Pulse Energy Dissipation2700 Joules
- Peak Impulse Current135,000 Amps
- LAN – Wires Protected8-Wires
- LAN – Compatibility10/100/1000 BASE-T
- LAN – Clamping Level60 ± 5V
- Coax – ShieldedYes
- Coax – Insertion Loss< 0.5 dB
- Coax – HD 1080 i/p ReadyYes
- Coax – Frequency Range0 MHz – 2.2 GHz
- Coax – ConnectionsFemale “F”, Gold Plated
- Coax – Clamping Level75V
- Coax – BidirectionalYes
Other Specifications
- Warning:WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov
Proposition 65 Warning
pdf_BlueBOLT_2_0_Info_Sheet.pdf | |
pdf_M4315-PRO_datasheet.pdf | |
pdf_M4315-PRO_manual.pdf | |
pdf_M4315-PRO_quick-start-guide.pdf |