xIn 4 | xOut 4 | xIO 4×4
- 1/2 Rack Form Factor.
- PoE – injectors included.
- xIn 4 – 4 analog mic/line inputs.
- xIO 4×4 – 4 analog mic/line inputs + 4 analog outputs.
- xOut 4 – 4 analog outputs.
- Optional rack and surface mounting kits sold separately.
Analog Inputs
Frequency Response |
20 Hz – 20 kHz, ± 0.5 dB. |
Channel Separation |
> 111 dB @ 1 kHz, +24 dBu. |
Connectors |
3.5 mm Phoenix® connectors. |
Number of Inputs |
Four (4) switchable balanced mic or line level. |
Nominal Input Level |
+4 dBu with 20 dB of headroom. |
Maximum Input Level |
+23 dBu. |
Mic pre-amp gain |
0, 11.8, 24, 44 or 54 dB switchable. |
Mic pre-amp EIN |
< -127dB with 150 ohm source impedance. |
CMRR |
> 76 dB @ 1 kHz, unity gain. |
Input impedance |
8k Ohms balanced, 4k Ohms unbalanced. |
Phantom power (per input) |
+48 VDC @ 10 mA maximum. |
Dynamic range |
> 116 dB, A-weighted. |
THD + Noise |
< -100 dB, unweighted; 1 kHz @ +22 dBu with 0 dB gain. |
Latency |
0.28 mS. |
Mechanical Specifications
Space Required |
Half rack unit (WDH: 20.83 cm x 22.86 cm x 4.37 cm / 8.2 in. x 9 in. x 1.72 in.) Depth does not include connector allowance. Allow at least 3 inches additional clearance for rear panel connections. Additional depth may be required depending upon your specific wiring and connections. |
Electrical |
PoE IEEE 802.3af Class 0, 10 Watts maximum. No line voltage switching required (100-250 VAC, 50-60 Hz). |
Ventilation |
Maximum recommended ambient operating temperature is 30 C / 86 F. Ensure that the left and right equipment sides are unobstructed (5.08 cm, 2 in minimum clearance). The ventilation should not be impeded by covering the ventilation openings with items such as newspapers, tablecloths, curtains, etc. |
Certifications or Compliance |
UL 60065, cUL 60065, IEC 60065, FCC 15.109:2015, FCC 15.109(g):2015, FCC 15.107:2015, (CISPR 32), EN 55032:2012, EN 55103-2:2009, EN 61000-3-3:2013, EN 61000-3-2:2006, ICES-003:2012, RoHS. |
Shipping Weight |
4.4 lbs. (2.0 kg) |
Analog Outputs
Frequency Response |
20 Hz – 20 kHz, ± 0.5 dB. |
Channel Separation |
> 111 dB @ 1 kHz, +24 dBu. |
Connectors |
3.5 mm Phoenix® connectors. |
Number of outputs |
Four (4) balanced line level. |
Nominal output level |
+4 dBu with 20 dB of headroom. |
Maximum output level |
+24 dBu (+22.8 dBu into a 2k Ohm minimum load). |
Output impedance |
300 Ohms balanced, 150 Ohms unbalanced. |
Dynamic range |
> 118 dB, A-weighted. |
THD + Noise |
< -105 dB, unweighted; 1 kHz @ +22 dBu with 0 dB gain. |
Latency |
0.60 mS. |
System
Sampling Rate |
48 kHz, ± 100 ppm. |
Dante Cable |
Standard CAT6, maximum device-to-device length = 100 meters. |
Architect and Engineer Specifications: xIO 4×4.
The half rack device shall provide four analog mic/line inputs that are adjustable from line to mic level with coarse gain and phantom power and four analog line outputs. Levels and phantom power shall be controllable via DSP modules in software. Audio connections shall be accessed via rear panel 3.5 mm Phoenix® connectors.
Network audio expansion shall be provided by the Dante protocol. The connector shall be 100 Base-T RJ45 utilizing CAT6 cable.
A designer software application shall be provided that operates on a Windows computer, with network interface installed, running Windows® 7 or higher operating system. Computer connection for configuration shall be via a hosting DSP unit’s rear panel Ethernet connector that communicates with the devices via Dante.
The front panel shall include indicators for POWER, ETHERNET, and DANTE.
Audio conversion shall be 24-bit, 48 kHz and the dynamic range shall not be lower than 115 dB, A-weighted with a maximum input level of +23 dBu and maximum output level of +24 dBu.
The device shall be powered over Ethernet (PoE) by an included 802.3af Class 0 PoE injector. The device shall meet UL/CSA and CE safety requirements and comply with CE and FCC Part 15 emissions limits. The device shall be RoHS compliant. The chassis shall be constructed of cold rolled steel, and may be surface mounted or mount into a standard 19” 1U EIA rack using available mounting kits. The device shall be a Symetrix xIO 4×4.